# Measure Against Tolerances

Many checks are measurements: a diameter, a length, a weight, a temperature. Kanoa judges each value against the limits set
for the item being made, so the same check can be used for many products. Your Quality Manager builds these checks and sets
their limits, so the check sheets you use will have their own names and measurements. This lesson uses the
**Machining - First Article Inspection**, if it has been created: the Quality Manager track builds it in
[Build a First Article Inspection](../5-quality-manager/5-build-a-first-article-inspection.md). Any other measurement
check works the same way.

## Open the Check

Measurement checks are often scheduled for you, for example when a machine starts a run, at a shift change, or every so
often. When one is coming due or due, the **Notifications** card on the machine's Operator Station counts it. Tap the card,
then tap the check. You can also find it on **Quality → Schedule → Active Checks** or **Check Table**.

1. Open the check.
2. Confirm the asset and the item are filled in. The item decides which limits apply.

{/*
TODO: Confirm on a gateway how the Notifications card reads for a scheduled measurement check and that tapping it opens
Active Checks with the machine selected.
*/}

:::info[In the First Article Inspection]
The check is scheduled when a machine enters **Production**, so the first part of each
run is measured. The machines make coupling pins (10 mm diameter), precision rods (15 mm) and shaft cores (25 mm). Each
part family has its own diameter tolerance, so the same **Diameter** check item judges each one correctly.
:::

## Enter the Measurements

1. Enter each reading. Some check items take more than one measurement: enter one reading in each box.
2. Fill in any other items, such as a visual check.
3. Submit the check.

When a check item takes more than one measurement, Kanoa keeps every reading and judges the combined result, such as their
average or their largest value. The check sheet decides which.

:::info[In the First Article Inspection]
The check has three items: **Diameter** (three measurements, judged on their average), **Length** (two
measurements, judged on the largest) and **Visual Defect Check**.
:::

## What Happens When a Value Is Out of Spec

Each tolerance has limits. Kanoa compares every value you enter against them.

| Your value is... | What Kanoa does |
| --- | --- |
| Outside the entry limits | Refuses it, with a message giving the allowed range. Check your reading and enter it again. |
| Between the control limit and the spec limit | Saves it as a pass, and highlights it in orange as a warning. |
| Outside the spec limits | Saves it as failed, and highlights it in red. |

For example, **Length** at CoreForge has a spec of 100 to 200 mm. Readings of 150 and 205 give a largest reading of 205,
so the check item fails.

After a failure:

1. Add a comment saying what you found and what you did. You can't submit a check sheet with a failure without one.
2. Submit the check.
3. Follow your plant's procedure for a failed check.

Your plant may also set a check sheet to schedule another check straight away when a check fails, or to email a team or
user. When that happens you'll see a new check on your schedule.

:::tip
Read the entry limits message before you retype. It tells you the range Kanoa accepts, which is often enough to spot a
misread gauge or a typing slip.
:::

::embed-section{src="../../kanoa-quality/attributes.md#tolerances" collapsed="true" summary="Reference Materials: Attribute Tolerances - What each limit means and how it's colored."}

## Check Your Understanding

1. Why can one measurement check be used for many different products?
2. Which value does Kanoa refuse to save?
3. A reading is between the control limit and the spec limit. Does the check fail?
4. What must you add before you can submit a check that has a failed item?

<details>
<summary>Answers</summary>

1. Kanoa judges each value against the limits for the item being made, and the item is filled in on the check.
2. A value outside the entry limits. Kanoa shows the allowed range.
3. No. It passes, but it's highlighted in orange as a warning.
4. A comment.

</details>